Environmental protection, Fig.9, Troubleshooting – Sealey SAC3153B User Manual

Page 5

Advertising
background image

fig.9

See fig.1 for location and section 6.2

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: guarantee is 24 months from purchase date, proof of which will be required for any claim.

iNFORMATiON: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK distributor, Sealey Group,

Kempson Way, suffolk Business Park

,

Bury st. edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

W e b

email

Original Language Version

6. TROUBLESHOOTiNG

FAULT

POSSiBLE CAUSE

REMEdY

1A) Pressure drop in the tank

Air leaks at connections

run compressor to max. pressure, switch off.

Brush soap solution over connections and look for

bubbles. tighten connections showing leaks.

If problem persists contact Authorised service Agent

1B) Pressure drop in the tank

Air leaks from safety valve

It should be replaced, unless leaking at a joint

which can be sealed.

1c) Pressure drop in the tank

Air leaks from cylinder head gasket

check tightness of head bolts. If leak continues

contact authorised service Agent

2) Pressure switch valve leaks when

compressor is idle

non-return valve seal defective

empty the air tank. referring to fig.9, remove the

non-return valve cap (3), spring (2) and seal (1).

clean the seal and its seat, or if necessary replace

the seal

3) Air leaks from tank body or tank welds

Internal corrosion caused by infrequent tank

draining or non permitted modifications to tank

tank could rupture or explode. cannot be repaired

diSCONTiNUE USE iMMEdiATELY

4A) motor stops and will not restart

thermal cut out has operated

Allow unit to cool for 30 minutes before restarting

4B) motor stops and will not restart

supply fuse has tripped

Press trip reset button (fig.2) and restart unit. If

repeated tripping occurs replace the check valve or

contact authorised service Agent

5) compressor stops and does not restart

motor failure

contact Authorised service Agent

6A) compressor does not stop at max. pressure

Pressure switch fault

contact Authorised service Agent

6B) compressor does not stop at max. pressure

filter clogged

Head gasket or valve fault

replace filter element.

contact Authorised service Agent

7) compressor noisy with metallic knock

Bearing or piston damage

contact Authorised service Agent

8) excessive moisture in discharged air

High humidity environment

drain tank after each use

Environmental Protection.

recycle unwanted materials instead of disposing of them as

waste. All tools, accessories and packaging should be sorted,

taken to a recycle centre and disposed of in a manner which is

compatible with the environment.

Parts support is available for this product. To obtain a parts listing and/or diagram,

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

sAc3153B/sAc3203B Issue no: 1 - 01/06/13