5. MAiNTENANCE

5.1. oPerAtIons to Be cArrIed out After tHe fIrst

5 WorKIng Hours:

a) check that all bolts/nuts are tight, particularly those

retaining the crank case and cylinder head.

5.2. oPerAtIons to Be cArrIed out After tHe fIrst

50 WorKIng Hours:

b) replace the lubricating oil - see para 5.5.

5.3.

oPerAtIons to Be cArrIed out dAIlY:

a) drain condensation by opening the valve located under

the tank (fig.6). Place a container under the valve and slowly

open the valve by turning counterclockwise.

5.4. oPerAtIons to Be cArrIed out eVerY 100 Hours

(or more frequently, if the compressor operates in a very

dusty atmosphere)

a) check oil level and, if necessary, top up.

b) remove the filter elements (see fig.7) and clean with

compressed air (wear eye protection).

dO NOT operate the

compressor without the filters as foreign bodies or dust could

seriously damage the pump.

c) check for oil leaks.

In order to keep the compressor in good working condition,

periodic maintenance is essential.

WARNiNG! Before performing any maintenance

operation, switch off the compressor, disconnect from

electricity supply and release all air from the tank.

iMPORTANT! Failure to carry out maintenance tasks may

invalidate the warranty on your compressor.

fig.6

drain valve underside

of receiver, ensure

shut on start up (4.3)

and drain daily (5.3.)

5.5. oPerAtIons to Be cArrIed out eVerY 200 Hours:

a) replace the lubricating oil. for oil specifications see 5.7.

remove the oil filler plug (see fig.4.B) then unscrew oil drain

plug (see fig.4) and drain the oil into a container.

drain when the compressor is hot so that oil drains rapidly

and completely. Incline compressor to ensure complete

drainage.

replace oil drain plug and refill through the oil filler

aperture. do not overfill. replace oil filler plug.

b) Check the automatic cut-out at max. pressure and the

automatic cut-in at 2bar below.

WARNiNG! Never mix different oils and dO NOT use

non-detergent/low quality oils as the compressor may be

damaged.

WARNiNG! dispose of waste oil only in accordance with

local authority requirements.

5.6.

oPerAtIons to Be cArrIed out eVerY 500 Hours:

a) replace air filter. (see fig.7)

b) check all tube fittings and electrical connections.

5.7.

recommended oils;

recommended oil for compressors, suitable for room

temperatures ranging from +5°c to +25°c.

seAleY cPo or equivalent sAe 40 compressor oil. room

temperature below +5°c: sAe 20 compressor oil.

5.8

iMPORTANT WARNiNG - Air contaminants taken into the

compressor will affect optimum performance. example: Body

filler dust or paint overspray will clog the pump intake filter

and may cause internal damage to pump/motor components.

Please note that any parts damaged by any type of

contamination will not be covered by warranty.

5.9

inspection of pressure tank both inside and out.

under the Pressure sYstems sAfetY regulAtIons

2000 it is the responsibility of the owner of the compressor to

initiate a system of inspection that both defines the frequency

of the inspection and appoints a person who has specific

responsibility for carrying out the inspection.

fig.7

fig.8

Axle bolt

spacers

Plain washer.

Plain washer/

spring washer/

spacer.

receiver leg

spring washer/

nut

Pneumatic wheel

receiver leg

swivel castor

nut/spring

washer

Bolt

Original Language Version

sAc3153B/sAc3203B Issue no: 1 - 01/06/13

© Jack sealey limited 2013

Advertising
This manual is related to the following products: