EXP Computer ThinCom PCMCIA Ethernet Modem Adapter User Manual

Page 35

Advertising
background image

APPENDIX A

- 31 -

S37:000 S90:000 S108:002 S109:062

S37:000 S90:000 S108:002 S109:062

Telephone Numbers:

Telephone Numbers:
&Z0 12345

&Z0 12345
&Z1 T4444444

&Z1 T4444444
&Z2 T12345

&Z2 T12345
&Z3 T 1 (123) 456-7890

&Z3 T 1 (123) 456-7890

&W

0

0

Store active profile in user profile 0

Store active profile in user profile 0

1

1

Store in

Store in active profile user profile 1

user profile 1

&Y

0*

Select stored profile 0 on power up

1

Select stored profile 1 on power up

&Zn=x

none

Store telephone number
To dial the stored telephone, use the

To dial the stored telephone, use the
ATDS=n command.

ATDS=n command.
x = 0, 9, A, B, C, D, #, *, T, P, R, W, @, ,,!,;

x = 0, 9, A, B, C, D, #, *, T, P, R, W, @, ,,!,;
n = 0-3

n = 0-3

%E

0

Disable Auto-retrain ( V.32 and V.32bis Only)

1 *

Enable Auto-retrain

%G0

0 *

Disable Auto Fallforward/fallback Rate

Renegotiation

1

Enable Auto Fallforward/fallback Rate

Renegotiation

%Q

none

Line signal quality
Range: 0-255

Range: 0-255
0 - 7 No Retrain

0 - 7 No Retrain

8 - 255 Modem performs a Retrain (i.e., if configured for %E1)

8 - 255 Modem performs a Retrain (i.e., if configured for %E1)

-Cn

0*

Diable data modem calling tone

1

Enable data modem calling tone

*

Value saved in NVRAM.

V.42, MNP 'AT' Commands

Command

Default

Function

%A

13

Set auto-reliable fallback character

%C

0

No data compression

1*

MNP 5 data compression control

\A

0

0

MNP block size

Maximum 64 characters

Maximum 64 characters

1

1

MNP block size

Maximum 128 characters

Maximum 128 characters

2

2

MNP block size

Maximum 192 characters

Maximum 192 characters

3*

3*

MNP block size

Maximum 256 characters

Maximum 256 characters

\Bn

none

Transmit break (n=0-9 Break lenght in 100 msec)

\C

0*

Does not buffer data

1

1

Buffers data for four seconds until 200 characters have been buffered or SYN character is detected, then switches to reliable mode. If the buffer fills,

Buffers data for four seconds until 200 characters have been buffered or SYN character is detected, then switches to reliable mode. If the buffer fills,
data is passed to the serial port.

data is passed to the serial port.

2

2

Does not buffer data. Switches to normal mode upon receipt of auto-reliable fallback character and passes it to serial port. This feature is used to

Does not buffer data. Switches to normal mode upon receipt of auto-reliable fallback character and passes it to serial port. This feature is used to
allow non-V.42 modems to connect immediately to a V.42 modem without data loss.

allow non-V.42 modems to connect immediately to a V.42 modem without data loss. Set auto-reliable buffer

\G

0 *

Disable modem port flow control

1

Set port flow control to XON/XOFF

\Jn

0 *

Disable Bps rate adjusting

Advertising
This manual is related to the following products: