Removing the sync to matrix script, The sync to matrix feature -28, Installation and operation, cont’d – Extron electronic Digital Video Scaler Series DVS 304 AD User Manual

Page 40

Advertising
background image

Installation and Operation, cont’d

DVS 304 • Installation and Operation

2-28

Removing the Sync to Matrix Script

If the Sync to Matrix feature is no longer being used, the script can be removed

from the DVS by the following steps:

1

.

Open the Signal Enhancements Windows Control program and connect to the

DVS via IP (not RS-232).

2

.

Under the Tools menu, select Sync DVS 304 to Matrix Switcher... . The Sync

DVS 304 to Matrix Switcher window opens.

3

.

Click Remove Script.

Minimize synchronization problems without using the Sync to Matrix

feature

This section describes how to manually implement the equivalent of the Sync to

Matrix feature without using a script loaded on the DVS 304, and instead relying

on a control system.
When operating the system using a manually configured control system (for which

Sync to matrix has not been setup), you can avoid synchronization problems that

cause unwanted image blanking or scrambling during input switches by doing the

following.

N

If the Sync to Matrix feature has been previously used, first see

Removing the

Sync to Matrix Script section above.

1

.

While setting up the switcher and the DVS to work together, set rthe RGB

delay on the matrix switcher, equal to, or greater than 1.0 second.

2

.

Create a tie on the matrix switcher from desired input X to the output number

that corresponds to the DVS 304’s Input 4.

3

.

Immediately (within 1 second) recall the input preset on the DVS 304

associated with the input X on the matrix switcher.

N

Input presets cannot be recalled via the DVS 304’s front panel. You can recall

them via SIS commands (see chapter 3, “Serial Communication”).

Advertising