4 universal LPG installation electrolux integrated barbecue

2. Adjust the turndown setting on the valve
å

е)FålTTED åREMOVEåTHEåKNOBSåFROMåTHEåVALVES

å

е2EMOVEåRUBBERåGROMMETSåFROMåCONTROLåPANELåHOLES

For non flame failure valve adjust the turndown screw
fully clockwise on each of the 4 valves using a small flat
blade screwdriver. The valve is now set correctly for LPG
operation (see diagram).

If flame failure fitted the turn down screw will need to be
adjusted after unit is installed, and unit is ready for testing.
This is done using a thin flat blade screw driver inserted
through hole in centre of shaft spindle (see diagram).

å

е&OLLOWINGåCONNECTIONåOFåGASåASåPERåSTEPSå  åLIGHTå
all burners and one at a time set the burner to the
lowest setting and check burner flame. Adjust turn
down screw clockwise to achieve a small steady
flame.

3.

Connect the test point adaptor to the barbecue gas inlet

å

е&ITåTHEåTESTåPOINTåADAPTORåENSURINGåTHEåBLUEåSEALINGå
washer is in place and the arrow is pointing in the
direction of gas flow. Do not over-tighten.

4.

Connect the hose to the test point adaptor

å

е!PPLYåTHREADåTAPEåORåSEALANTåTOåTHEåMALEåTHREADåONå
the hose and screw into the test point adaptor.

5. Replace the ‘gas type’ sticker
å

е,OCATEåTHEå@.ATURALå'ASåSTICKERåLOCATEDåONåTHEå
barbecue gas inlet and remove it. Put the Universal
LPG sticker in its place.

Preparing the unit for Universal LPG installation.
This barbecue is supplied set up for Natural Gas and is
labelled accordingly. A Universal LPG conversion Kit is
included to enable conversion to Universal LPG.

NOTE
#ONVERSIONåOFåTHISåUNITåTOå5NIVERSALå,0'åMUSTåBEåCARRIEDå
out by a qualified licensed person and a Certificate of
Compliance must be issued to the owner on completion of
the installation and conversion.

The required components for conversion have been
supplied. The components are:
så (OSEåANDåREGULATORåASSEMBLY
sе е3MALLåPLASTICåBAGåCONTAININGååBRASSåINJECTORS
sе е5NIVERSALå,0'åSTICKER
så åDATAåPLATEåLABEL
så )NSTRUCTIONåSHEET
så åTESTåPOINTåADAPTOR
så åSEALINGåWASHER

1. Change the injectors
å

е2EMOVEåTHEåFRONTåCOVER

å

е2ELEASEåTHEåBURNERåRETAINERåCLIPåASåSHOWNе

е

е5NSCREWåANDåREPLACEåTHEååINJECTORåNIPPLESåLOCATEDå
in the end of each tube feeding the burners. The
Universal LPG injectors have a 0.95mm diameter
orifice in them. They appear substantially smaller
than the Natural Gas injectors.

å

е2E FASTENåTHEåCLIPåTOåRETAINåTHEåTUBEåINåTHEåBURNERå
Do not over tighten or distort supply tube.

å

е&ITåTHEåFRONTåCOVERåBACKåONåANDåFASTENåSCREWS

Universal LPG installation

LPG injector

turndown screw for
non-flame failure valve

if flame failure valve fitted,
turn down screw inside
shaft with a small flat-blade
screwdriver

test point adaptor –
ensure arrow is pointing
in the right direction

hose with tapered thread
– thread tape required

sealing washer

barbecue gas inlet

remove spring clip
by rotating over
burner tube end

front cover