Port monitoring display keys, Setting the system recovery level – Extreme Networks Summit 300-48 User Manual

Page 137

Advertising
background image

Port Monitoring Display Keys

Summit 300-48 Switch Software User Guide

137

• Receive Fragmented Frames (RX Frag)

— The total number of frames received by the port were of

incorrect length and contained a bad FCS value.

• Receive Jabber Frames (RX Jab) —

The total number of frames received by the port that was of

greater than the support maximum length and had a Cyclic Redundancy Check (CRC) error.

• Receive Alignment Errors (RX Align) —

The total number of frames received by the port that

occurs if a frame has a CRC error and does not contain an integral number of octets.

• Receive Frames Lost (RX Lost) —

The total number of frames received by the port that were lost

because of buffer overflow in the switch.

Port Monitoring Display Keys

Table 48 describes the keys used to control the displays that appear when you issue any of the

show

port

commands.

Setting the System Recovery Level

You can configure the system to automatically reboot after a software task exception, using the
following command:

config sys-recovery-level [none | critical | all]

Where the following is true:

none

— Configures the level to recovery without a system reboot.

critical

— Configures ExtremeWare to log an error into the syslog and automatically reboot the

system after a critical exception.

all

— Configures ExtremeWare to log an error into the syslog and automatically reboot the system

after any exception.

The default setting is

none

.

Table 48: Port Monitoring Display Keys

Key(s)

Description

U

Displays the previous page of ports.

D

Displays the next page of ports.

[Esc] or [Return]

Exits from the screen.

0

Clears all counters.

[Space]

Cycles through the following screens:

Packets per second

Bytes per second

Percentage of bandwidth

Available using the

show port

utilization

command only.