Determining audio switcher circuit card population – Extron electronic 6400s User Manual

Page 51

Advertising
background image

5-9

Matrix 3200/6400 Series • Upgrades and Troubleshooting

Determining Audio Switcher Circuit Card
Population

The drawing above shows the layout of the input
and output audio circuit card slots on the rear
panel of the Matrix 6400 Audio Switcher. The 8 card
slots to the left are bracketed and labeled INPUTS,
the 8 card slots to the right are bracketed and
labeled OUTPUTS. Each audio card supports 8
stereo channels and each card slot (input and
output) is labeled to identify the physical connector
range covered by the card plugged into a slot (low
number = top connector, high number = bottom
connector on card).

The chart to the right shows the REQUIRED circuit
card population for every possible matrix
configuration. The following Matrix 6400 Audio
configurations are supported:

8 inputs x 8, 16, 24, 32, 40, 48, 56, 64 outputs
16 inputs x 8, 16, 24, 32, 40, 48, 56, 64 outputs
24 inputs x 8, 16, 24, 32, 40, 48, 56, 64 outputs
32 inputs x 8, 16, 24, 32, 40, 48, 56, 64 outputs
40 inputs x 8, 16, 24, 32, 40, 48, 56, 64 outputs
48 inputs x 8, 16, 24, 32, 40, 48, 56, 64 outputs
56 inputs x 8, 16, 24, 32, 40, 48, 56, 64 outputs
64 inputs x 8, 16, 24, 32, 40, 48, 56, 64 outputs

An example matrix configuration of 24x16 would
require audio input cards in the left 3 slots (1-8, 9-
16 and 17-24) of the INPUTS section and audio
output cards in the left 2 slots (1-8 and
9-16) of the OUTPUTS section. If the cards are not
installed as shown for each matrix size, the Extron
Matrix 6400 System Virtualization/Control
Software will be unable to accurately virtualize the
system. The Audio Input circuit cards (PN# 70-069-
01) plug into connectors INPUTS 1-8 through 57-64,
the Audio Output circuit cards (PN# 70-070-01)
plug into connectors OUTPUTS 1-8 through 57-64.
It is not possible to plug the circuit cards in upside
down or inputs into outputs nor vice versa.

AC POWER INPUT

FUSE: 250V 5.0A TT

IN

OUT

100-240V 5.0A MAX 50/60Hz

DISCONNECT PO

WER CORD BEFORE SER

VICING

MKP COMM.

BME COMM.

RS232/RS422

A

B

C

D

E

A

B

C

D

E

BME

ADDRESS

ANAHEIM, CA
MADE IN USA

4

-

+

INPUTS

OUTPUTS

IN

1 - 8

IN

9 - 16

IN

17 - 24

IN

25 - 32

IN

33 - 40

IN

41 - 48

IN

49 - 56

IN

57 - 64

OUT

1 - 8

OUT

9 - 16

OUT

17 - 24

OUT

25 - 32

OUT

33 - 40

OUT

41 - 48

OUT

49 - 56

OUT

57 - 64