Terminating resistance and id address settings, 1] setting the terminating resistance, 2] setting the id address – Elmo PTC-200C User Manual

Page 26

Advertising
background image

- 25 -

10. TERMINATING RESISTANCE AND ID ADDRESS SETTINGS

The ID address of the RS-485 and the terminating resistance can be set by using the

switches Nos. 1 through 9 of the DIP Switch (10) located on the bottom of the Main Unit.

Switch No.

1 – 8

9

10

Function

Sets the ID address.

Turns ON/OFF the terminating resistance

None

[1] Setting the terminating resistance

The terminating resistance is built in each Camera, and it can be turned ON/OFF by using

the pin No. 9 of the DIP Switch (10) of each Camera. To prevent the attenuation of the

signal, turn ON the terminating resistances of the 2 Cameras located at both ends of the

longest route, of all cameras to be connected to the RS-485 interface, and turn OFF the

terminating resistances of the other Cameras.

DIP Switch (10)

[2] Setting the ID address

The ID address for communication of the RS-485 can be set by using the switches No. 1

through 8 of the DIP Switch (10). (Refer to "Setting the ID address" table - P26, 27)

Advertising