11. TROUBLESHOOTING HINTS

If the problem still remains after checking the above, consult your nearest dealer or

authorized ELMO service center.

Symptom

No images on TV

monitor

Out of focus

No operation via

the wireless remote

control

The preset position

is blurry

Possible cause/remedy

• Cable is not properly connected to the video-in terminal

of monitor.

• The AC adapter is disconnected from the wall AC outlet.

• The AC adapter output plug is disconnected from the DC

jack of the Camera.

• Zoom is set at TELE to display only white/black part of

the material.

• The LED is lit red, and the Camera is in the OFF

position.

• The LED is lighting, and the OFF Timer mode of the

Camera power is working. (See P.19)

• The cable is not connected to each output terminal.

• The iris is not in the proper position.

(If the iris is fully closed, the image cannot be seen.)

• The chosen video output type (NTSC) is different from

the system of the monitor .

• The focus is in the Manual mode. Set the focus to the

Auto mode by pressing the AUTO button of focus. (See P.16)

• The light/shade contrast of the object is too low. (See P.16)

• The object is moving too fast. (See P.16)

• Operation is made with wrong ID number settings. (See P.18)

• Operate within the operation range of the wireless

remote control. (See P.7)

• Check the remaining battery life of the wireless remote

control.

• The sunlight or the light from the inverter fluorescent

lamp or the like is received by the infrared sensor on the

Camera. Relocate the Camera or block the light. (See P.7)

• The pin No. 1 of the DIP Switch (4) is ON.

• The Camera head has been moved directly due to some

cause.

Adjust the Camera direction by setting the "RESET"

button to the normal position. (See P.15)