3.9. ASSEMBLING THE PLASTERBOARD CLADDING

PLASTERBOARD HOLE SIZE (2000mm x 670mm):


Y= H – 133 -> H = measurement taken from the floor to the lower part of the frame crosspiece (figure A).

-> 133 = minimum measurement (with feet completely screwed).

Z= P – 46 -> P = measurement taken form the existing wall to the rear frame upright (figure B).

-> 46 = minimum measurement required by the wall locking brackets.

Using the formulas shown, calculate the height of the plasterboard wall hole from the floor and the distance of

the wall from the original wall. To reinforce the hole on the wall use uprights (M) with a maximum depth of

30mm.