2.9. CHIMNEY

Often, if it is underestimated, it prevents the correct functioning of the

"chimney system".
The draught of the flue pipe also depends on its chimney.
It is therefore vital that, if it has been hand-crafted, the development of

the four relief sections correspond to more than twice the internal

cross-section of the flue pipe.
Since it should always be higher than the ridge of the roof, the

chimney will be exposed to all weather, and so an industrial-

type chimney is recommended.

Industrial chimney

with prefabricated

stacked elements.
Allows excellent

smoke disposal.

Traditional hand-

crafted chimney.
The correct outlet

cross-section should

be at least twice the

internal cross-

section of the flue

pipe, ideally 2.5

times its size.

Steel flue pipe

chimney with

internal smoke-

deflector cone.
Allows excellent

smoke disposal.

The chimney must:

Have an inner section equal to that of the flue.

Have a working outlet section of at least double that of the

inner section of the flue pipe.

Be built in such a ways as to prevent rain, snow and any

foreign bodies from penetrating the flue pipe.

Be positioned so as to ensure adequate dispersion of smoke

and, in all cases, outside the reflux area in which back-

pressures are likely to form.

In the case of paired flue pipes, the solid

combustibility or upper storey chimney shall be at

least 50 cm higher than the others in order to avoid

the transfer of pressure from one paired pipe to the

other.
The chimney must not have any obstacles within a

range of 10 metres, including walls, pitches and trees.

If this is the case, then raise it at least 1 metre above

the obstacle and in the event of other chimneys

nearby, space them at least 2 metres apart and in all

cases the chimney must protrude from the ridge of the

roof by at least 1 metre.






UPPER STOREY OR SOLID
COMBUSTIBILITY

LOWER STOREY

1

m

t

0,

5

m

t

YES

NO