20 c m m in . 30 cm – MCZ Kasai User Manual

Page 8

Advertising
background image

Chapter 2

USE AND MAINTENANCE MANUAL

page

8

Installation recommendations in compliance with UNI 10683

Technical dept. - All rights reserved by MCZ GROUP S.p.A. - Reproduction

prohibited

2.2. POSITIONING

In the case of concurrent installation with other heating appliances,

provide the appropriate air inlets for each one (according to the

instructions for each appliance).

Installing the stove in a bedroom or bathroom is not

permitted, nor in any room where another heating

appliance is installed without an independent air

inflow.
It is forbidden to position the stove in rooms with an

explosive atmosphere.

The floor of the room where the stove is installed

must be suitably sized to withstand its weight.

2.2.1.

Safe distances













If particularly delicate objects are present, such as furniture, curtains or

sofas, increase the stove clearances substantially.

If the stove is positioned on a flammable floor, we

recommend you ensure it is suitably insulated.
Heat-sensitive or flammable objects and parts

cannot be stored near the stove; keep such objects

or parts at a minimum front clearance of 100 cm

from the outermost point of the appliance.

KASAI Non-flammable

walls *

Flammable walls

*

A=15cm

B=20cm

A=20cm
B=30cm

20

c

m

m

in

.

30 cm.

* Leave an appropriate distance from the walls in any case in order to allow easier appliance maintenance.

A

B

Advertising