Thermo Pride C Premiere Series User Manual

Page 14

Advertising
background image

The pressure/temperature chart on the wiring diagram is to serve only as a guide. Pressures shown are
realistic averages, which will vary somewhat with changes in air temperatures, air volume across the

e

evaporator coil, condenser coil, and changes in humidity - both inside and outside, and variations in lin
length.

: DO NOT UNDER ANY CIRCUMSTANCES; HEAT THE REFRIGERANT CYLIN

WITH A TORCH OR BY ANY OTHER MEANS OTHER THAN WARM WATER. EXCESSIV
PRESSURES GENERATED IN THIS MANNER MAY WEAKEN THE REFRIGERANT CONTAINE
AND RESULT IN A CYLINDER EXPLOSION!

If a charge must be added to the system, 410A refrigerant must be removed from the storage cylinder as a

DER

E

R

liquid. Slowly add liquid refrigerant through the suction service port while the compressor is running.

RE

ION F

O

S


If you are going to be operating the system

the

sys

he ite

elow to

its lon

d


1. There should be a crankcase heater installed on compr
2. A low ambie

ntro 45° co

ct) added

24 v

3. Suction line accumulator.
4. Confirm com

sor s

erhea


These items will assist in preventing liquid floodback,

COMMENDAT

S OR OPERATING AT L WER OUTDOOR AMBIENT CONDITION

F, Thermo Products specifies you must add to

urability of the compressor.

essor.

below 6

gevity and

tem t

ms listed b

aid in

nt co

l (

nta

to the

olt control circuit.

pres

up

t.

flooded starts, and refrigerant migration during off

cycle. These situations are detrimental to the life of a compressor.

USER INFORMATION

The following maintenance points should be reviewed periodically to assure that the air conditioning
system will operate properly.

1.) Keep clean air filters in the path of the air flow. If excessively dirty air filters are not changed, this

will cause poor performance of the system, put unnecessary strain on the compressor and this may
cause the system to lock out. Never operate system without clean air filters in place.

2.) Keep the outside condenser coil clean by spraying with a garden hose from the inside of the coil

outward.

WARNING: TURN OFF OR DISCONNECT THE ELECTRICAL

POWER SOURCE BEFORE CLEANING THE CONDENSER COIL.

If the air conditioning system will not operate, check the following points before calling a qualified
serviceman.

1.) Is the sub-base of the thermostat switched to the “COOL” position?

cessary to wait

several hours before the unit will restart. If this happens with any regularity, call your local
serviceman.


2.) Is the temperature setting on the thermostat low enough to bring the air conditioner on?

3.) If the fan motor or compressor have locked out on thermal-overload, it may be ne

14

Advertising