SAF-HOLLAND XL-PH10409UM PH-419 Series Rigid Type Pintle Hook User Manual

Page 10

Advertising
background image

10

XL-PH10409UM-en-US Rev C · 2012-08-03 · Amendments and errors reserved. © SAF-HOLLAND, Inc.

Mounting Instructions

7. Pintle Hook, Plunger and

Air Chamber without
Bracket Installation

IMPORTANT: Holland

recommends

a Type 24 air chamber.

Before installing the pintle hook, plunger and
air chamber without bracket (Figure 9),
make sure that the mounting structure is
of sufficient strength to support the rated
capacity of the pintle hook. Refer to SAE J847
for structural performance requirements.

1. Install the pintle hook without an

air chamber bracket to the mounting
structure, using the mounting bolt hole
pattern specified (Figure 11).

2. Verify mounting structure hole pattern

matches the dimensions listed (Figure 11).

3. Insert and tighten all six (6) new 3/4"

diameter Grade 8 bolts, ASTM Grade C
lock nuts and hardened 3/4” washers
(Figure 10). Torque to 200 ft.-lbs.
/tN QFS4"&+

Figure 9

Figure 10

Figure 11

4*9  
(3"%&
#0-54

4*9  (3"%&$
-0$,/654

4*9  8"4)&34

6.62"

(168.2 mm)

5.00"

(127.0 mm)

2.50"

(63.5 mm)

Ø 3.25"

(82.6 mm)

7.88"

(200.0 mm)

5.19"

(131.8 mm)

3.31"

(84.1 mm)

Ø .81"

(20.6 mm)

THRU (6 REQ.)

2.13"

(54.0 mm)

2.00"

(50.8 mm)

2.38"

(60.3 mm)

.38"

(9.5 mm)

5.00"

(127 mm)

Advertising