Mounting instructions, Installation options, Pintle hook only installation – SAF-HOLLAND XL-PH10409UM PH-419 Series Rigid Type Pintle Hook User Manual

Page 7

Advertising
background image

7

XL-PH10409UM-en-US Rev C · 2012-08-03 · Amendments and errors reserved. © SAF-HOLLAND, Inc.

Mounting Instructions

Figure 1

Figure 3

5.00"

(127.0 mm)

Ø 3.25"

(82.6 mm)

2.00"

(50.8 mm)

2.38"

(60.3 mm)

2.13"

(54.0 mm)

3.31"

(84.1 mm)

Ø .81" (20.6 mm)

THRU (6 REQ.)

5.19"

(131.8 mm)

7.88"

(200.0 mm)

2.50"

(63.5 mm)

6.62"

(168.2 mm)

4. Installation Options

The PH-419 rigid mount pintle hook is
available in three (3) configurations: pintle
hook only, page 7; pintle hook, plunger and
air chamber with bracket, page 8 and pintle
hook with plunger and air chamber without
bracket, page 10. Each configuration requires
a different installation which is described in
the following sections. Be sure to verify your
configuration before beginning installation.

5. Pintle Hook Only Installation

Before installing the pintle hook only (Figure 1),
make sure that the mounting structure is of
sufficient strength to support the rated capacity
of the pintle hook. Refer to SAE J847 for
structural performance requirements.

1. Install the pintle hook to the mounting

structure using the bolt hole pattern as
specified (Figure 3).

2. Verify mounting structure hole pattern

matches the dimensions listed (Figure 3).

3. Insert and tighten all six (6) new 3/4"

diameter Grade 8 bolts, ASTM Grade C
lock nuts and hardened 3/4” washers
(Figure 2). Torque to 200 ft.-lbs.
/tN QFS4"&+

Figure 2

4*9  
(3"%&
#0-54

4*9  
(3"%&$
-0$,/654

4*9  8"4)&34

Advertising