Mounting instructions – SAF-HOLLAND XL-PH10409UM PH-419 Series Rigid Type Pintle Hook User Manual

Page 9

Advertising
background image

9

XL-PH10409UM-en-US Rev C · 2012-08-03 · Amendments and errors reserved. © SAF-HOLLAND, Inc.

Mounting Instructions

4. Install the air chamber by aligning the

air chamber assembly and plunger
with the pintle hook. Make sure the
plunger moves freely within the pintle
hook plunger chamber (Figure 7).
Attach the air chamber to the assembly
(Figure 12). Bolt together the air
chamber assembly and pintle hook using
two (2) new 3/4” diameter Grade 8
bolts, ASTM Grade C lock nuts, and
hardened 3/4” washers (Figure 8).

5. Torque all six (6) new 3/4" diameter

Grade 8 bolts and ASTM Grade C lock
OVUTUPGUMCT /tN QFS
SAE J429.

6. Connect the air supply to the air chamber

and check for proper operation.

IMPORTANT: Consult the vehicle

manufacturer for
information regarding
proper plumbing,
air source, and
overpressure protection.

7. Adjust the plunger as needed per detailed

instructions in Section 8, page 12.

Figure 7

Figure 8

1-6/(&3

1*/5-&)00,1-6/(&3$)".#&3

"*3$)".#&3

580  
(3"%&
#0-54

580  (3"%&$
-0$,/654

580  8"4)&34

Advertising