8

SPECIFICATION
Electrical

Temperature
Scale

Celsius or Fahrenheit user-selectable

Measurement
Range

K-Type -50°C to 1000°C, (-50°F to
1832°F)

Resolution

0.1°C or 0.2°F

Accuracy

Accuracy is specified for operating
temperatures over the range of 18°C
to 28°C (64°F to 82°F), for 1 year, not
including thermocouple error.
±(0.1% rdg + 1°C) on -50°C to 1000°C
±(0.1% rdg + 2°F) on -50°F to 1832°F
±(0.05% rdg + 1.4°F) -58°F to -328°F

Sensor

Thermistor temperature sensor

Range

0°C to 60°C, (32°F to 140°F)

Resolution

0.1°C/°F

Accuracy

±2°C on 0°C to 10°C
±0.5°C on 10°C to 45°C
±2°C on 45°C to 60°C
±4°F on 32°F to 50°F
±1°F on 50°F to 113°F
±4°F on 113°F to 140°F

Relative Humidity

Sensor

Capacitive Humidity Sensor

Range

0% to 100% RH

Accuracy

±2.5% at 25°C (77°F), 10% to 90% RH
±5% at 25°C (77°F), 0% to 10% RH,
90% to 100% RH