002e replacement drive capacity too small, 002f verify not started; unit never initialized – Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 269

Advertising
background image

Error and Notification Messages

www.lsi.com/channel/products

257

It is recommended that you execute a file system check when the rebuild
completes.

Under Windows, right-click on your drive icon and choose

Properties >>

Tools >> Check Now.

For Mac OS X, you can use the First Aid tab in the Disk Utility—select the
disk on the left and then click Verify Disk. If verification encounters
problems, you can then use the Repair Disk option on the same screen.

Under Linux and FreeBSD use the fsck command.

For OpenSolaris and VMware you should follow your operating system’s
guide to perform a file system check.

See Also

“Starting a Verify Manually” on page 152

“Enabling or Disabling Auto-Verify for a Unit” on page 107

“Setting Overwrite ECC (Continue on Source Error When Rebuilding)” on
page 108

002E Replacement drive capacity too small

Event Type

Error

Cause

The storage capacity of the drive you are using as a replacement drive is too
small and cannot be used.

Action

Use a replacement drive equal to or larger than the drives already in use

002F Verify not started; unit never initialized

Event Type

Warning

Cause

A verify operation has been attempted by the 3ware RAID controller, but the
unit has never been initialized before. The unit will automatically transition to
initializing mode and then start a verify.

Advertising