10 pulse frequency integration with liquid product – ProSoft Technology MVI56-AFC User Manual

Page 292

Advertising
background image

Reference

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 292 of 316

ProSoft Technology, Inc.

February 25, 2011

14.5.10 Pulse Frequency Integration with Liquid Product

Start Offset

End Offset

Data Format

Type

Description

10

11

Accumulator

Snapshot

Accumulator totalizer, net

12

13

Floating point

Snapshot

Accumulator residue, net

14

15

Floating point

Flow weighted average Flow rate, net

16

17

Floating point

Flow weighted average Temperature

18

19

Floating point

Flow weighted average Pressure

20

21

Floating point

Flow weighted average K-Factor

22

23

Floating point

Flow weighted average Meter Factor

24

25

Floating point

Flow weighted average Density Input

26

Word

Flow weighted average Water content, % e-2

27

Word

Flow weighted average Corrected density (scaled integer)

28

29

Floating point

Flow weighted average Pulse Frequency

Example 1
Find the Net Accumulator addresses at archive 1 (latest daily archive) for the first

4 meters.

Primary Modbus Slave Input
Register Address

Description

10 and 11

Net Accumulator Totalizer from archive 1 - Meter 1

2510 and 2511

Net Accumulator Totalizer from archive 1 - Meter 2

5010 and 5011

Net Accumulator Totalizer from archive 1 - Meter 3

7510 and 7511

Net Accumulator Totalizer from archive 1 - Meter 4

Example 2
Find the Net Accumulator addresses at archive 0 (current daily archive) for the

first 4 meters.

Primary Modbus Slave
Holding
Register Address

Description

9910 and 9911

Net Accumulator Totalizer from archive 0 - Meter 1

11910 and 11911

Net Accumulator Totalizer from archive 0 - Meter 2

13910 and 13911

Net Accumulator Totalizer from archive 0 - Meter 3

15910 and 15911

Net Accumulator Totalizer from archive 0 - Meter 4