M-ii – Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-II User Manual

Page 23

Advertising
background image

1.3 SERVOPACK Ratings and Specifications

1-5

1

Outline

∗1.

Speed regulation by load regulation is defined as follows:

∗2.

Refer to

4.2.10 Velocity Control (VEL CTRL: 3CH)

of

Σ

-V Series User’s Manual MECHATROLINK-II Commands

(Manual No.: SIEP S800000 54) for details on the soft start function.

I/O

Signals

Sequence

Input

Input

Signals

which can

be allocated

Number of

Channels

3 ch

Functions

• Homing deceleration switch (/DEC)
• External latch (/EXT 1)
• Forward run prohibited (P-OT), reverse run prohibited

(N-OT)

• Forward external torque limit (/P-CL), reverse external

torque limit (/N-CL)

Signal allocations can be performed, and positive and
negative logic can be changed.

Sequence

Output

Fixed Output

Servo alarm (ALM)

Output

Signals

which can

be allocated

Number of

Channels

3 ch

Functions

• Positioning completion (/COIN)
• Speed coincidence detection (/V-CMP)
• Rotation detection (/TGON)
• Servo ready (/S-RDY)
• Torque limit detection (/CLT)
• Speed limit detection (/VLT)
• Brake (/BK)
• Warning (/WARN)
• Near (/NEAR)

Signal allocations can be performed, and positive and
negative logic can be changed.

Communi-

cations

Function

Personal Computer

Communications (USB)

Supports SigmaWin+.
Based on the USB 1.1 standard (12 Mbps).

LED Display

ALM (red), RDY (green), COM (green)

MECHATROLINK-

II

Communications Setting Switches

DIP Switch
(SW1, SW2)

Number of pins: four pins

×

2 switches (Refer to

4.1.1

)

Analog Monitor

Number of points: 2
Output voltage:

±

10 VDC (linearity effective range

±

8 V)

Output through the analog monitor unit (model: JUSP-PC001-E), the connec-
tion cable (model: JZSP-CF1S06-A3-E), and the analog monitor cable
(model: JZSP-CA01-E).

Dynamic Brake (DB)

Not supported.

Regenerative Processing

Not supported.

Overtravel Prevention (OT)

Deceleration to a stop or free run to a stop at P-OT or N-OT

Protective Function

Overcurrent, overvoltage, overload, and so on.

Utility Function

Gain adjustment, alarm history, JOG operation, origin search, and so on.

(cont’d)

Speed regulation

=

No-load motor speed

Total load motor speed

Rated motor speed

×

100%

-