1 basic settings for position control, 1) reference pulse form, 2) input filter selection – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 108

Advertising
background image

5 Operation

5.4.1 Basic Settings for Position Control

5-28

5.4.1

Basic Settings for Position Control

This section describes the basic settings for position control.

(1) Reference Pulse Form

Set the reference pulse form using Pn200.0.

(2) Input Filter Selection

Parameter

Reference Pulse Form

Input

Pulse

Multiplier

Forward Run

Reference

Reverse Run

Reference

Pn200

n.

0

[Factory setting]

Sign + pulse train
(Positive logic)

n.

1

CW + CCW pulse train
(Positive logic)

n.

2

Two-phase pulse train
with 90

°

phase differen-

tial

×

1

n.

3

×

2

n.

4

×

4

n.

5

Sign + pulse train
(Negative logic)

n.

6

CW + CCW pulse train
(Negative logic)

H level

PULS
(CN1-1)

SIGN
(CN1-3)

L level

PULS
(CN1-1)

SIGN
(CN1-3)

L level

CW
(CN1-1)

CCW
(CN1-3)

L level

CW
(CN1-1)

CCW
(CN1-3)

90

Phase A
(CN1-1)

Phase B
(CN1-

3)

90

Phase A
(CN1-1)

Phase B

(CN1-

3)

L level

PULS
(CN1-1)

SIGN
(CN1-3)

H level

PULS
(CN1-1)

SIGN
(CN1-3)

H level

CW
(CN1-1)

CCW
(CN1-3)

H level

CW
(CN1-1)

CCW
(CN1-3)

Parameter

Meaning

When Enabled

Classification

Pn200

n.0

[Factory setting]

Uses the reference input filter for line driver signal.
(Up to 1 Mpps)

After restart

Setup

n.1

Uses the reference input filter for open-collector sig-
nal. (Up to 200 kpps)

n.2

Uses the reference input filter 2 for line driver signal.
(1 Mpps to 4 Mpps)

Advertising