3 Wiring and Connection

3.3.2 Output Signal Allocations

3-18

3.3.2

Output Signal Allocations

Output signals can be allocated to I/O signal connectors (CN1) in accordance with the parameter setting of

Pn50E, Pn50F, Pn510, and Pn512.

(1) Checking Factory Settings

Factory settings can be checked using the following parameters.

Allocates /COIN signal to CN1-7.

Allocates /V-CMP signal to CN1-7.

Allocates /TGON signal to CN1-9.

Allocates /S-RDY signal to CN1-10.

Pn50E = n . 3 2 11

Analog

Not to use /CLT signal.

Not to use /VLT signal.

Not to use /BK signal.

Not to use /WARN signal.

Pn50F = n . 0 0 0 0

Analog

Not to use /NEAR signal.

Reserved (Cannot be changed)

Not to use /PSELA signal.

Reserved (Cannot be changed)

Pn510 = n . 0 0 0 0

Analog

Not to invert CN1-7 output signals.

Not to invert CN1-9 output signals.

Not to invert CN1-10 output signals.

Reserved (Cannot be changed)

Pn512 = n . 0 0 0 0

Analog