Warning indication and remedies

If the indicators flash in a manner other than described above, unplug the AC power cord and make sure
the ON/STANDBY indicator turns off, then plug the AC power cord into the wall outlet and turn on the
projector.
If the problem still persists, consult with qualified Sony personnel.

Updating software The projector software is being updated.

Indicator status

Number of flashes

Meaning/Remedies

Twice

The top cover is not properly attached.
Check the attachment of the top cover. If it has been loosened
due to a strong impact to the projector, consult with qualified
Sony personnel.

Three times

The light source does not light properly.
Unplug the AC power cord and make sure the ON/STANDBY
indicator turns off, then plug the AC power cord into the wall
outlet and turn on the projector.

Twice

The temperature in the projector is abnormal.
Perform the following.

Check if the air filter is clogged, then clean or replace it
(page 48).

Check if the ventilation holes (intake/exhaust) are not
blocked by the wall or an object and secure a sufficient gap.

Check the ambient temperature and use the projector within
the range of operating temperature.

Indicator status

Operating status

Description

(Flashes in orange)

(Off)

(Lights in red)

(Flashes in red)

(Lights in red)

(Flashes in red)

(Flashes in red) (Flashes in red)

Both indicators flash

If there is any problem or an error message
appears on the screen, refer to “Messages List” or