Floor protection – England's Stove Works TRANQUILITY 17VL User Manual

Page 16

Advertising
background image

Page | 16

FLOOR PROTECTION

R Value Calculation 

An easy means of determining if a proposed alternate floor protector meets requirements is 

to follow this procedure: 

1)

Convert specification to R‐value: 

i

R‐value is given – no conversion is needed  

ii

k‐factor is given with a required thickness (T) in inches:  R = 1/k x T 

iii

C‐factor is given:  R = 1/C 

2)

Determine the R‐value of the proposed alternate floor protector: 

i

Use the correct formula given in step 1 (above) to convert values not expressed as 
“R.” 

ii

For multiple layers, add R‐values of each layer to determine overall R‐value. 

3)

If  the  overall  R‐value  of  the  system  is  greater  than  the  R‐value  of  the  specified  floor 
protector, the alternate is acceptable. 

EXAMPLE: 

The  specified  floor  protector  should  be  ¾”  thick  material  with  a  k‐factor  of  0.84.    The 
proposed  alternate  is  4”  brick  with  a  C‐factor  of  1.25  over  1/8”  mineral  board  with  a  k‐
factor of 0.29. 

Step (a):  Use formula above to convert specification to R‐value.  

R = 1/k x T = 1/0.84 x .75 = 0.893 

Step (b):  Calculate R of proposed system. 

 

4” brick of C = 1.25, therefore R brick = 1/C =1/1.25 = 0.80 

 

1/8” mineral board of k = 0.29, therefore Rmin.bd. = 1/0.29 x 0.125 = 0.431 

 

Total R = R

brick

 + R

mineral board 

= 0.8 + 0.431 = 1.231 

Step (c):  Compare proposed system of R of 1.231 to specified R of 0.893.  Since proposed 

system R is greater than required, the system is acceptable. 

Definitions: 

Thermal conductance 

=   C   =     _____Btu____ 

=   ____W____ 

 

 

                                  (hr)(ft

2

)(deg F)             (m

2

)(deg K) 

 

Thermal conductivity 

=   k 

=    __(Btu)(inch)__ 

=   ___W____     =   ____Btu____ 

 

 

 

                    (hr)(ft

2

)(deg F) 

      (m)(deg K)           (hr)(ft)(deg F) 

 

Thermal resistance 

=   R 

=      (ft

2

)(hr)(deg F) 

=   (m

2

)(deg K) 

                  Btu   

 

Advertising