Troubleshooting – England's Stove Works TRANQUILITY 17VL User Manual

Page 23

Advertising
background image

Page | 23

TROUBLESHOOTING

Issue 

Cause 

Solution(s)

Stove smokes into room 

1. Weak Draft

1.1 Be certain chimney is sufficiently tall to 
meet the 10‐3‐2 rule. 

 

 

1.2 Add additional height to the chimney.

 

2. Negative Pressure in 
the Home 

2.1 Add an outside combustion air hookup to 
the unit. 

Fire is hard to start 

3. Weak Draft

3.1 Be certain chimney is sufficiently tall to 
meet 10‐3‐2 rule. 

 

 

3.2 Add additional height to the chimney 
system. 

 

4. Cold Chimney

4.1 Heat the flue first by burning crumbled 
newspaper in the stove. 

 

 

4.2 Install an insulated chase around external 
chimneys. 

 

5. Downdraft in 
Chimney 

5.1 Be certain chimney is sufficiently tall to 
meet 10‐3‐2 rule. 

 

 

5.2 Try heating the flue with a hair‐dryer to 
correct the draft. 

Glass is dirty 

6. Wet or Green Wood

6.1 Only burn wood that is seasoned for at 
least one year and that is dry and free of ice 
and snow. 

 

7. Operating Stove at 
Low Burn Rate 

7.1 Operate the stove at higher burn rates to 
allow the air‐wash system to keep the glass 
clean. 

 

8. Wood Loaded Too 
Close to Glass 

8.1 Never load wood so that it is touching the 
ceramic glass viewing window. 

Coals build up in firebox 

9. Operating Stove at 
High Burn Rates 

9.1 Reduce combustion air control and allow 
coals to burn down before reloading. 

Fire burns out of control 

10. Excessive Draft

10.1 Reduce chimney height. 

 

11. Air Leakage

11.1 Inspect window and door gaskets and 
replace if necessary. 

 

12. Burning Excessively 
Dry Wood 

12.1 Only burn seasoned cord wood.  Do not 
burn kiln dried wood or pallet wood. 

Excessive smoke from stack 

13. Operating Stove at 
Low Burn Rate 

13.1 Operate the stove at a higher burn rate 
which will create secondary combustion. 

 

14. Wet or Green 
Wood 

14.1 Only burn wood that is seasoned for at 
least one year and that is dry and free of ice 
and snow. 

 

15. Not Charring Fresh 
Wood Load 

15.1 Char the fresh wood load until it is 
completely ignited and active secondary 
combustion is present in the firebox. 

 