INSTALLATION

Additional Venting Information 

 Do not mix and match components from different pipe manufacturers when assembling 

your venting system (i.e. Do NOT use venting pipe from one manufacturer and a thimble 
from another). 

 We require a minimum chimney height of 15.0 ft.  Chimney systems shorter than this 

may not create the amount of draft which is required to operate this wood burning unit. 

 Do not use makeshift compromises when installing the venting system; have existing 

chimney systems inspected before use and be certain all new chimney systems are 
installed to the manufacturer’s specifications and with only UL listed components (ULC if 
Canada). 

 Prefabricated venting systems used for this stove must be listed to ULC S629 (Canada) 

and UL 103HT (US). 

 Never install a draft inducer or any other system which increases the natural draft of the 

chimney; similarly, do not install a barometric or stovepipe damper with this unit. 

 Never use single wall or double chimney connector as a chimney system; never pass 

either type of chimney connector through a combustible wall without carefully following 
the manufacturer’s instructions and those listed in the following page on Wall Pass‐
Throughs.  NEVER pass chimney connector through an attic, floor, closet or roof. 

 Only use 24 gauge MSG black single wall chimney connector or UL Listed (ULC if Canada) 

double wall chimney connector. 

Single Wall Chimney Connector Installation

WARNING

 INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. 
 HOT! Do not touch!  Severe burns or clothing ignition may result. 
 Glass and other surfaces are hot during operation.

Flue

 Gas

 Direct

ion

 

Crimped or male end of 
single wall chimney 
connector must face down. 

Fasten each single wall 
chimney connector joint 
with three sheet metal 
screws. 

The male end of single wall 
chimney connector is 
installed facing down so that 
any liquid creosote in the 
flue will run into the unit 
instead of onto the outside 
of the pipe (the natural draft 
in the chimney system will 
prevent smoke leakage at 
the joints). 