Empire Comfort Systems DVP48FP3 EN User Manual

Page 17

Advertising
background image

21759-6-0608

Page 17

MAXIMUM HORIZONTAL

RUN WITH NO VERTICAL

RISE AND 90° ELBOW

MAXIMUM HORIZONTAL

RUN WITH MINIMUM

VERTICAL RISE AND

90° ELBOW

minimum

Figure 25

Figure 24

MINIMUM HOLE LOCATION DIMENSIONS FOR

THROUGH THE WALL HORIZONTAL INSTALLATIONS

WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE

Positioning the Fireplace

Determine the exact position of the appliance so the direct vent

termination will be centered (if possible) between two (2) studs. This

will avoid any extra framing. All vent kit pipes should be assembled

on the unit after the unit is moved into the final position.
Cutting the Hole (Figures 23)

After the fireplace has been positioned in its permanent location,

the hole through the exterior wall of the house can be cut. This hole

must be 12" (305mm) high x 10" (254mm) wide with its center line

determined by the amount of vertical rise and horizontal run of the

termination. See Figure 23. When locating the hole it must be noted

that the bottom of the cap must be 12" (305mm) above the ground

level, and top of the cap must be no less than 18" (457mm) below

a combustible projection, and no closer than 9" (229mm) to any

wall running parallel to vent termination. See Figure 24.

A

CENTER OF

ELBOW

STRAIGHT

OUT

(MINIMUM)

2

30

FIREPLACE

SERIES

HARD ELBOW DIMENSIONS

"A"

"B"

"C"

DVP42FP

43-1/2"

(1105mm)

5"

(127mm)

7"

(178mm)

DVP48FP

43-1/2"

(1105mm)

5"

(127mm)

7"

(178mm)

FIREPLACE

SERIES

FLEX PIPE 90 DEGREE BEND

"A"

"B"

"C"

DVP42FP

46"

(1143mm)

5"

(127mm)

7"

(178mm)

DVP48FP

46"

(1143mm)

5"

(127mm)

7"

(178mm)

Figure 23

Advertising
This manual is related to the following products: