Clearances locating fireplace, Figure 4 – Empire Comfort Systems DVP48FP3 EN User Manual

Page 8

Advertising
background image

21759-6-0608

Page 8

Mantel Chart (Figure 3)

Figure 3

Clearances (Figure 4)

Clearance from top front edge of fireplace to ceiling is 36"

Clearance from side of fireplace to adjacent sidewall is 6".

(914mm)

Figure 4

15”

(381mm)

TOP EDGE OF FIREPLACE

12” (305mm)

10” (254mm)

MANTEL

COMBUSTIBLE TRIM AND MANTELS

ALLOWED IN SHADED AREA

4”

5”

6”

7”

8”

9”

11”

13 3/4”

3/4”

1 ½”

2 1/4”

3”

3 3/4”

4 ½”

6”

8”

3”

Figure 5

Note: Island (C) and Room Divider

(D) installation is possible as long

as the horizontal portion of the

vent system (H) does not exceed

20 feet with a minimum vertical

run of 8 feet. See details in Venting

Section.
When you install your Direct Vent

Fireplace in (D) Room divider or

(E) Flat on wall corner positions,

a minimum of 6 inches clearance

must be maintained from the

perpendicular wall and the front

edge of the appliance.

Figure 2

Combustible Material

No greeting cards, stockings or ornamentation of any type should

be placed on or attached to the fireplace. The flow of heat can

ignite combustibles.

CABINET

INSTALLATION

FLUSH WALL

INSTALLATION

ROOM DIVIDER

INSTALLATION

CORNER

INSTALLATION

ANGLED CORNER

INSTALLATION

ISLAND

INSTALLATION

Clearance to Combustibles

Back

0" (0 mm)

Side

0" (0 mm)

Floor

0" (0 mm)

Top Stand-off

0" (0 mm)

Top Framing Edge

3" (76 mm)

SEE MANTLE CHART FOR

MAXIMUM MANTLE DEPTH

NON-COMBUSTIBLE

FIRST 3 (SEE MAGNIFIED

VIEW)

NAILING

FLANGES

GLASS FRONT

TOP FRAMING

LEDGE

FINISHED WALL

(COMBUSTIBLE)

SEE MANTLE CHART

FOR MINIMUM HEIGHT

OF MANTLE ABOVE UNIT

2" x 4" HEADER

STAND OFF

3" (76 mm) HEIGHT

ABOVE TOP OF

FIREPLACE

3"

CLEARANCES

LOCATING FIREPLACE

Advertising
This manual is related to the following products: