COM3 – RS232/RS485/RS422 interface

Supported on Channel C of the external Quad UART, COM3 port can be configured by

software as RS232 or RS485/RS422.
The port is buffered to RS232 (or RS485/RS422) levels with ±15kV ESD protection.

RS232 interface supports full handshaking and modem control signals. The maximum

baud rate on this channel is 921.6 Kbaud. COM3 RS232 interface is connected to the

connector J19, and RS485/422 interface is connected to the connector J18. For pin

assignment and connector details, see

J18 – Serial port (RS485/422) – COM3

on page

87

and

J19 – Serial ports – COM3/4

on page

88

.

Three control outputs of I

2

C GPIO expander (I

2

C address 0x21) are used to select one

of the operating modes RS232, RS485 or RS422. The selection is implemented by

using two control signals (U3_RS232EN, U3_RS422EN) to enable/disable the associated

transceivers. The control signal combinations are shown in the following table:

U3_RS232EN
(EXP1_GPIO 0)

U3_RS422EN
(EXP1_GPIO 1) Selected COM3 function

1 X RS232
0

0

RS485 Full duplex

0

1

RS422 Half duplex

U3_RS232EN and U3_RS422EN are at logic ‘1’ upon

reset.

The control signal U3_TERM# is used to enable/disable the RS485/422 line

termination and must be enabled if the ZEUS board is at the end of the network. The

following table shows the usage of U3_TERM# signal:

U3_TERM# (EXP1_GPIO 2)

Termination resistors (120

Ω)

0 Connected
1 Disconnected

U3_TERM# is at logic ‘1’ upon reset.

The RS485/422 driver (LTC2859) on ZEUS features a logic-selectable reduced slew

mode that softens the driver output edges to control the high frequency EMI emissions

from equipment and data cables. The reduced slew rate mode is entered by taking the

SLO# pin low, where the data rate is limited to about 250kbps. Slew limiting also

mitigates the adverse effects of imperfect transmission line termination caused by

stubs or mismatched cables.

U3_RS485_SLO# (EXP2_GPIO 5) Slew rate
0 Reduced
1 Normal