Jumpers, User, Jp1 – user jumpers – Eurotech Appliances ZEUS PXA270 User Manual

Page 93: Jp2 – battery disconnect

Advertising
background image

ZEUS Technical Manual

Connectors, LEDs and jumpers

© 2007 Eurotech Ltd Issue D

93

Jumpers

There are six user selectable jumpers on the ZEUS. Their use is explained below.

JP1 – User jumpers

Connector:

8-way, 2.54mm (0.1") dual row through-hole header

Pin Signal

name Pin Signal

name GPIO

1 GND

2 USER_LINK1 CPU_GPIO

13

3 GND

4 USER_LINK2 CPU_GPIO

102

5 GND

6 USER_LINK3 EXP1_GPIO

6

7 GND

8 USER_LINK4 EXP1_GPIO

14

These are four user configurable jumpers connected to GPIO pins of PXA270 and

MAX7313 GPIO Expander 1.

JP1 Description

GPIO read as ‘0’

GPIO read as ‘1’ (Default)

User jumpers 1 and 2 (GPIO 13 and 91) may be

connected to an external momentary push switch and

used to wake the ZEUS from sleep.

JP2 – Battery disconnect

Connector:

2-way, 2.54mm (0.1") through-hole header

Pin Signal

name

1 Battery

Plus

Terminal

2

Battery Backup switch input


Normally supplied with jumper removed.

This jumper is used to disconnect the backup battery to prevent it from draining.

JP2 Description

Battery connected

Battery disconnected (default)

1

2

8

7

1 2

Advertising