Simple diagnostics, Status of accessory inputs – Estate E-SC 1102 User Manual

Page 27

Advertising
background image

Simple Diagnostics

Diagnostics using the Power light on your Master Control
Board.
The P light has a diagnostic function. There are 4 statuses.

1. Steady light indicating main power is ON and

the battery is charged

2. Flashing slowly (lights every second) indicates no main

power but the battery is charged.

3. Flashing quickly (lights every 1/4 of a second)

indicates main power on but discharged battery

4. Light OFF indicates no main power and discharged

battery.

Status of accessory inputs.

The Master Control Board has the ability to verify the status of the terminal board inputs. To ac-
cess this function:

When all LEDs are off (both lettered and numbered) press P2. The statuses of the accessory ter-
minals in the following chart will be shown in the lettered LEDs column.

LED ON =
Closed Contact
LED OFF =
Open Contact

When you have
finished checking,
press P2 again to
exit.

If you do not, the
LED status check
will stay active for
5 minutes and then
the board returns
to all LEDs OFF.

WARNING:
When you access
the input status
function all acces-
sories are powered, even with the gate idle. P1 is active and can be used to open and close
the gate.

7.1

Normal Operation
idle LED lights

LED

ON

OFF

A = OFF

A = Terminal 1,
Open/close function

Opening/closing

device is triggered.

Opening/Closing

device is not trig-

gered.

B = OFF

B = Terminal 2,
Single leaf open/
close

Opening/closing

device is triggered.

Opening/Closing

device is not trig-

gered.

C = ON

C = Terminal 3,
Stop Command

Motion stop device is

in place and not

triggered or jumper is

in place..

Motion stop device

has been triggered or

is not connected.

D = ON

D = Terminal 4,
Opening safety de-
vice

Motion stop device is

in place and not

triggered or jumper is

in place..

Safety device has

been triggered or is

not connected.

E = ON

E = Terminal 5,
Closing safety de-
vice

Motion stop device is

in place and not

triggered or jumper is

in place..

Safety device has

been triggered or is

not connected.

1 = OFF if single
ON if dual

1 = Terminal 6,
Slave Board

Slave Board is

connected.

Slave board is not

connected.

Advertising