Standard System
Overview and Safety
Zones


The system display to the right is a
recommended standard system.
Other approved accessories can be
installed. Photo sensors and a flash-
ing light indicating gate movement
is recommended for safety purposes.

IMPORTANT
Preliminary Checks:

To ensure safety and an efficiently operating automated system, make sure the follow-
ing conditions are observed.

The gate and column must be suitable for being automated. Check that the structure
is sufficiently strong and rigid, and its dimensions and weights conform to those
indicated on page 1.

Make sure the leaves move smoothly without any irregular friction during entire
travel.

Make sure the hinges are in good condition. Ball bearing hinges are ideal for gates
weighing over 200 lbs. or over 10’ in length.

Make sure the gate is plumb and level.

The fence post must be secured in the ground with concrete. This will prevent
alteration of alignments and leveling during installation and during cycles.

1.2

1,2 Estate Swing Operator
3 Photocells (not included)
4 Master control board
5 Slave control board
6 Push button opening device (not included)
7 Receiver extension (not included)
8 12Vdc flashing lamp (not included)
9 Positive stop
10 AC transformer

Notes: 1) Do not extend operator connection cables
2) When laying electrical cables, use
appropriate rigid and/or flexible tube
3) Do not run any wires in the same conduit as
110 AC power that may be in the area. This
will cause unwanted interference