Powering up a enterasys matrix n1 chassis, Powering up a enterasys matrix n1 chassis -5, Esd grounding receptacle -5 – Enterasys Networks 7S4280-19-SYS User Manual

Page 39: Figure 3‐2

Advertising
background image

Powering Up a Enterasys Matrix N1 Chassis

Enterasys NAC Controller Hardware Installation Guide 3-5

Figure 3-2 ESD Grounding Receptacle

Powering Up a Enterasys Matrix N1 Chassis

To power up a Enterasys Matrix N1 Chassis with ac power supplies, refer to 

Figure 3‐3

 and 

proceed as follows:

1.

Plug one end of each power cord (supplied with the chassis) into the ac power sockets on the 
back of the N1 Chassis. See 

Figure 3‐3

 on page 3‐6 for the power connections.

2.

Plug each of the power cords into separate dedicated 115 Vac, 15 A receptacles.

3.

Ensure that the Power LED on each power supply is green, located on the front panel of the 
N1 Chassis.

4.

Ensure that all fans in the fan tray unit are operating properly when power is received from 
the power supply modules (fan tray LED will be green, located on the front panel of the N1 
Chassis). For more information on the power supply LEDs (Power and Fan), refer to 

LANVIEW LEDs

” on page 2‐2.

1 ESD grounding receptacle

Note: To install the NAC Controller PEP, refer to the

Chapter 4

,

NAC Controller PEP Installation

section for the installation instructions. Before you power up the Enterasys Matrix N1 Chassis, it is
recommended that you complete the installation of the NAC Controller PEP in the chassis.

FAN

STATUS

PS1

STATUS

PS2

STATUS

N1

GROUND

STRAP

7C111

N1 7C111

d

GROUND

STRAP

N1

1

Note: For power redundancy, each of the power cords from the two power supplies must be
connected to dedicated 15-Ampere ac power circuits.

Advertising