The nac controller policy configuration, Setup the vlan configurations, Nac controllers require separate domains – Enterasys Networks 7S4280-19-SYS User Manual

Page 84: The nac controller policy configuration -16, Nac controller pep com port location -16

Advertising
background image

The NAC Controller Policy Configuration

6-16 Initializing the NAC Controller

The NAC Controller Policy Configuration

Review the following considerations prior to configuring policy on NAC Controller PEP devices:

Setup the VLAN Configurations

NAC Controller PEP VLAN configuration must conform with the requirements of your network 
topology. During NAC Controller Engine management initialization for Out‐Of‐Band 
management configurations, you entered a management VLAN for this NAC Controller. For 
Out‐Of‐Band configurations, this management VLAN entered during initialization is pushed 
down to the PEP. 

For In‐Band management, the NAC Controller management VLANs are configured. The 
management VLANS are VLAN 1 for L2 and VLAN 90 for L3. There are also a number of VLANs 
configured such as 3056 for Port Mirroring or 3089 for Quarantine. It is important that you note 
these defaults and determine if they are desirable or in conflict with VLANs already present in 
your network. 

To display current VLAN settings and make any changes to VLAN configurations provide a 
console connection to the NAC Controller PEP host.0.1. 

For L2 access to the CLI for NAC Controller PEP configuration, connect the console to the NAC 
Controller PEP COM port. The COM port location is shown in 

Figure 6‐23

. The NAC Controller 

PEP CLI prompt will display.

Figure 6-23 NAC Controller PEP COM Port Location

Use the show port vlan host.0.1 command to display the current VLAN configuratin for this NAC 
Controller PEP. Use the show vlan command to display all configured VLANs. Once you have 
determined changes that may be required, reference the DFE‐Platinum and Diamond Series 
Configuration Guide for information pertaining to VLAN configuration. 

NAC Controllers Require Separate Domains

The NAC Controller can be configured in one of two modes of operation: L2 or L3. The mode of 
operation controls how connecting end systems are detected by the NAC Controller on the 
network and is selected based on where the NAC Controller is positioned in the network in 
relation to these end systems. If the NAC Controller is positioned before the first routed boundary 
for connecting end systems closer to the access edge of the network, the L2 NAC Controller mode 
is utilized. If the NAC Controller is positioned after the first routed boundary deeper inside the 
network, the L3 NAC Controller mode is utilized.

Advertising
This manual is related to the following products: