Troubleshooting, General, Ir control – ELAN Home Systems V883 User Manual

Page 25: Symptom cause solution

Advertising
background image

E L A N H O M E S Y S T E M S

© ELAN Home Systems 2006 • All rights reserved.

Page 23

V883

INSTALLATION MANUAL

6. Troubleshooting

SYMPTOM

CAUSE

SOLUTION

No power up.

1. No AC power.

Connect Power Cord to AC outlet.

Check AC circuit breaker.

1. Blown fuse.

Replace fuse w/ T0.4AL type fuse
(T0.2AL for 240V version).

General

SYMPTOM

CAUSE

SOLUTION

No source or zone selected
from IR controller (keypad,
hand-held remote, etc.).
IR LED does NOT flash
when button pressed.

1. IR controller not programmed.

Program IR controller.

Verify IR signal path wiring.
Check keypads, IR sensors, IR
distribution blocks, V883 IR Input
jack, IR emitters, etc.

IR Control

2. IR signal path wiring bad.

No source or zone selected
from IR controller (keypad,
hand-held remote, etc.).
IR LED DOES flash when
button pressed.

1. Incorrect IR commands
programmed (not V883
commands).

Verify/correct IR programming.

Intermittant or no source or
zone control from IR control-
ler (keypad, hand-held
remote, etc.). IR LED flickers
or is lit constantly.

IR flooding.

Check IR receivers or V883 front
IR sensor for ambient light or
plasma TV flooding.

Incorrect source and/or zone
selected.

Incorrect V883 IR commands
programmed.

Verify/correct IR programming.

2. UNIT ID DIP switches incorrect. Verify/correct DIP switches.

Advertising