Setup/config-module – ELSA Cable User Manual

Page 111

Advertising
background image

Description of the menu options

ELSA MicroLink Cable

R10

3

Default-lease-
time-minute(s)

Here you can enter the period of validity that is assigned if the host makes no request.

The DEFAULT value of 500 minutes equals approximately 8 hours.

Table-DHCP

In the DCHP module, the 'Table-DCHP' option allows you to verify (or look up) the
assignment of IP addresses to the relevant computers. This table has the following
layout:

IP-address: IP address assigned

Node-IP: The computer’s Ethernet address

Timeout: Time remaining until the assignment becomes invalid

Hostname: The computer’s name in plain text if it was transmitted in the request

Type: This field contains additional information on the assignment.

The 'Type' field specifies how the address was assigned. This field can assume the
following values:

new: The computer has made its initial request. The DHCP server verifies the

uniqueness of the address that is to be assigned to the computer.

unkn.: While verifying uniqueness, it was determined that the address has

already been assigned to another computer. Unfortunately, the DHCP server has
no means of obtaining additional information on this computer.

stat.: A computer has informed the DHCP server that it has a fixed IP address.

This address can no longer be used.

dyn.: The DHCP server assigned an address to the computer.

Setup/Config-module

This menu allows you to enter settings for router configuration options. The menu has
the following layout:

IP-address

Node-ID

Timeout

Hostname

Type

10.1.1.10

00a0570308e1

500

ELSA

new

/Config-module

Configuration module settings

Password-required

Password required on/off if there is no password

Switch-Off-mode

Configuration of the On/Standby switch

Standby

Standby status

Config-aging-minute(s)

Time limit for remote configuration connections

Advertising