Troubleshooting, 1 control board self-diagnosis – Electrolux Shirt Finisher F4VA1 User Manual

Page 15

Advertising
background image

15

Figure 7.3 - Self diagnosis example

7. Troubleshooting

Refer to Table 7.4 for solutions to the most common malfunction situ-
ations.
If the proposed solutions do not work, enter self-diagnosis (para-
graph 7.1) to determine if there are failed components.

WARNING - DO NOT SERVICE THE MACHINE YOURSELF
Call the service center in any of the following cases:

the machine has a problem that is not listed in table 7.4

none of the remedies proposed by the table work

control board self-diagnosis shows one or more failures.

7.1 Control board self-diagnosis

The control board is equipped with a self-diagnosis software that can
detect common problems to the pneumatic circuit.
1.

To enter self-diagnosis mode, press

and

together for two

seconds. The letter “C” appears on the PROG display.

2.

Press button

once. The letter F appears on the PROG dis-

play. The other displays (STEAM, MIX/ PAUSE, AIR) show infor-
mation concerning the status of the pneumatic circuit:

If there is no failure, the displays show: F -- -- --

If there are failures, the display STEAM shows the number
of failures occurred (use + or – to scroll all the referenc-
es). The display MIX/PAUSE shows the code of the failed
component. The display AIR shows the code of the type of
failure.

Failure references are displayed using the codes in tables 7.1 and
7.2.

Figure 7.3 shows an example:
The pneumatic circuit has more than one failures.
The displays show information regarding failure number 2: the back
clamp solenoid valve has no power.

To erase faults memory, press PROG until the displays
show: F -- -- --

To exit self-diagnosis program, press

and

together until the

displays STEAM, MIX, PAUSE, AIR show pressing times.

Table 7.1

Number displayed
in the Air display

The following fault has occurred

00

Neutral and phase are inverted

01

No power to the component

02

Short circuit at the component

Table 7.2

Number in the
Mix Pause dis-
play

The following component has failed

06

Solenoid valve E7 - Sleeve arms relaxation

07

Solenoid valve E5 - Open front clamp

08

Solenoid valve E6 - Sleeve arms positioning

09

Solenoid valve E4 - Front clamp side move-
ment

10

Solenoid valve E3 - Rear clamp

11

Coil of remote control switch VT2 - Suction
motor

12

Solenoid valve E2 - Suction

13

Solenoid valve E1 - Collar clamp

14

Coil of remote control switch VT1 - Blower
motor

15

Solenoid valve E11 - Cuff clamp right

16

Steam valve E12

17

Solenoid valve E10- Cuff clamp left

21

Solenoid valve E14 - Carriage down

22

Solenoid valve E13 - Carriage up

23

Solenoid valve E8 - Side clamps

24

Solenoid valve E17 - Open side expanders

28

Solenoid valve E26 - Sleeve arms counter-
pressure