Troubleshooting

Table 7.4 - Troubleshooting

Problem

Possible cause

What the user should do

The machine does
not start

No power to machine

Check there is electrical power in the facility
Check connection to power lines
Turn on the main power switch

The display is dim

Brightness of the display set too
low

Increase brightness by pressing button + on the control panel

The collar clamp does
not close

The clamp is excluded

Press the COLLAR exclusion button on the control panel to deselect (when the light
is off the clamp works)

Air pressure is inadequate or ab-
sent

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)

The carriage does not
move

The parameter H06 is set to 03,
04 or 05

Change the setting of the parameter (see table 5.2)

Reflective material is worn out

Replace reflective material strip

The photocell beam does not hit
the reflective material

Check that the photocell has not been moved. If necessary, redirect the photocell
beam on the reflective material and lock well the photocell position

The front clamp does
not move

Clamp is excluded

Remove the exclusion by pressing the FRONT button on the control panel (when
the light is off the clamp is active)

Air pressure is inadequate or ab-
sent

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)

The rear clamp does
not move

Clamp is excluded

Remove the exclusion by pressing the REAR button on the control panel (when the
light is off the clamp is active)

Air pressure is inadequate or ab-
sent

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
Check and regulate clamps pressure. Minimum pressure is 3 bar
(Figure 4.3, knob 18 and gauge 17)

Both side clamps do
not move

Clamps are excluded (parameter
H05 set to 00)

Set parameter H05 to 01

Air pressure is inadequate or ab-
sent

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
Check and regulate clamps pressure. Minimum pressure is 3 bar
(Figure 4.3, knob 18 and gauge 17)

Both side expanders
do not move

Air pressure is inadequate or ab-
sent

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
Check and regulate clamps pressure. Minimum pressure is 3 bar
(Figure 4.3, knob 18 and gauge 17)

Both sleeve arms do
not move

The arms are excluded

Press the ARMS exclusion button on the control panel to deselect (when the light
is off the arms work)

Air pressure is inadequate or ab-
sent

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)

No steam from ma-
chine

Steam feed valve closed

Open steam feed valve

Steam time set at zero

Set steam time greater than zero

No blowing

Blowing time set at zero

Set blowing time greater than zero

Inadequate ventila-
tion

Blowing adjustment set too low

Shift the blowing adjustment lever (12 - Figure 4.3) towards the + mark