4 alarm setup menu – EverFocus 410H User Manual

Page 39

Advertising
background image

3.4 ALARM SETUP MENU

In the ALARM SETUP MENU, we define :

(1) ALARM:

ENABLE: Enable alarm detection.

DISABLE: Disable alarm detection.

(2) ALARM TYPE:

N. O. : Normal Open alarm.

N. C. : Normal Close alarm.

N.O. Trans.: When the alarm is triggered, buzzer starts to function no matter how long the alarm

duration is set until you set it back to N.O.

N.C. Trans.: When the alarm is triggered, buzzer starts to function no matter how long the alarm

duration is set until you set it back to N.C.

(3) ACTIVE CAMERA:

Active camera setting, from camera 01~08. You can set the camera which corresponds to the

place where the alarm is located.

Note: The recording camera number in an event depends on the alarm nu mber, and the active camera

images will not be recorded. Example: You assign camera 3 as the active camera to alarm 1.

When the alarm 1 is triggered, camera 3 will be displayed and camera 1 will be recorded.

37

Advertising
This manual is related to the following products: