EverFocus 410H User Manual

Page 40

Advertising
background image

(4) DURATION:

Buzzer noise and event record duration of an alarm, from 1 sec to 99 seconds. The default value is

5 seconds.

(5) ALARM OUTPUT:

The setting of alarms which are NONE and 1, where 1 means the alarm is enabled.

(6) ALARM EMAIL:

Select “YES ” for sending an email when alarm occurs. The email address can b e set in the

NETWORK SETUP MENU.

(7) BUZZER: Alarm buzzer.

ENABLE: To enable an alarm buzzer.

DISABLE: To disable an alarm buzzer.

(8) ALARM NETWORK:

YES: Enable alarm network.

NO: Disable alarm network.

(9) MAIN MON: Display on a main monitor when an alarm occurs.

NO CHANGE: Nothing changes on the display in the main monitor when an alarm occurs.

FULLSCREEN: A full screen will pop up when an alarm occurs.

(10) CALL MON: Display on a call monitor when an alarm occurs.

NO CHANGE: Nothing changes on the display in the call monitor when an alarm occurs.

SEQUENCE: Display in the sequence mode when an alarm occurs.

ACTIVE CAMERA: Display the active camera in full screen mode to the call monitor.

(11) SUMMARY :

Dial Jog to change items in the SUMMARY table.

All alarm’s statuses are shown in SUMMARY tables. These tables are for checking alarm

overall statuses, but not for setting.

Note : Please check APPENDIX C to see other available alarm input / output functions.

38

Advertising
This manual is related to the following products: