Extreme Networks Icron WiRanger User Manual

Page 23

Advertising
background image

User Guide

17

Symptoms/Cause

Remedy

All LEDs on both the
LEX unit and REX unit
are on but the device
does not operate
correctly

Cause:

a) The USB device is

malfunctioning.

b) The computer does

not recognise the
USB device.

c) The application

software for the
device is not
operating.

d) The WiRanger is

malfunctioning.

1. Disconnect the WiRanger from the computer.

2. Connect the USB device directly to the USB

port on the computer.

3. If the device does not operate properly,

consult the user documentation for the device.

4. If the device operates properly when directly

connected to the computer, connect another
device (of a different type) to the WiRanger.
Connect the WiRanger to the computer.

5. If the second device does not operate, the

WiRanger may be malfunctioning. Contact
Technical Support for assistance (see page
20).

6. If the second device does operate properly,

the first device may not be compatible with the
WiRanger. Contact Technical Support for
assistance (see page 20).