Enterasys Networks BRIM-E6 User Manual

Page 32

Advertising
background image

APPENDIX A: EPIM SPECIFICATIONS

Page 28

BRIM-E6 USER’S GUIDE

power output at 25C equals -16.4 dBm. For a 4C temperature increase,
multiply the typical coefficient (-0.15 dBm) by four, and add the result to
typical output power (4 x -0.15 dBm + -16.4 dBm = -17.0 dBm)

Note: The above transmitter power levels and receive sensitivity levels
represent Peak Power Levels after optical overshoot. You must use a Peak
Power Meter to correctly compare the above values to those you measure
on any particular port. If you measure Power Levels with an Average

Parameter

Typical

Transmit Power:

-15.1 dBm

Transmit Budget:

14.4 dBm

Receive Sensitivity:

-29.5 dBm

Maximum Receive
Power:

-6.99 dBm

Bit Error Rate:

Better than
10

-10

Advertising