Gs w set barcode module width, Gs ~ enter debug mode, Gs w – Epson LABELWRITER SE450 User Manual

Page 55

Advertising
background image

Commands

ASCII

GS W Thin Thick

Decimal

29 87 Thin Thick

Hex

1D 57 Thin Thick

Parameters

Thin

thickness of thin bars

Thick

thickness of thick bars

GS w Set Barcode Module Width

Description

Selects the horizontal size of a barcode module. The parameter n represents the
thickness of the thin bars (in dots). Each dot measures .0049 inches in 203 dpi and
.0073 inches in 138 dpi. With Code 3 of 9, Interleaved 2 of 5, and Codabar barcodes,
the thick bars will be automatically adjusted to 2 * n.

Expression

ASCII

GS w n

Decimal

29 119 n

Hex

1D 77 n

Parameters

n

the desired horizontal size (in dots) of thin barcodes; with Code 3 of 9, Interleaved 2 of 5, and

Codabar, thick barcodes = 2 * n

GS ~ Enter Debug Mode

Description

Prints the received printer codes either as a Hex or ASCII dump. This allows you to
debug print problems. The debug mode remains in effect until the printer is powered
off.

Expression

ASCII

GS ~ n

Decimal

29 126 n

Hex

1D 7E n

Parameters

n = “a”

ASCII dump of received characters

n = “h”

Hex dump of received characters

49