4. Insert blower assembly into interior, bottom of firebox. Posi-

tion blower assembly so that you align the notch on back of

blower assembly with the center screw on firebox back, then

push the blower assembly against firebox back. The blower

wheel must be centered with the back wall of the firebox. The

magnets on the back and bottom of blower assembly will suf-

ficiently hold blower assembly in place.

Note: For field installation of blower assembly, it may be easier to

remove rear cover panel to install blower. This eliminates

the need to remove brick liner panels, but the blower would

have to be installed prior to installing the firebox into a

wall or chase. See Figure 28.

5. Once the blower assembly is in position, locate the plug but-

ton in the top right rear corner of the firebox. Remove the

plug with a standard screwdriver and discard plug.

6. Next, find the fan control switch and wire assembly. Feed the

wires through the hole at the top of the firebox, and secure the

fan control switch with (2) #6 screws provided. See Figure

29.

7. The fan control wires will slide down between the firebox

and outer wrap near the blower assembly. See Figure 29.

8. One fan control wire will have a 1/4” female terminal that

must be attached to the open terminal on the blower motor.

See Figure 32, Connection A.

9. The other fan control wire has a 1/4” male terminal. Attach

this terminal to the open terminal on the blower power cord.

See Figure 32, Connection B

10. Route the wires away from moving parts of the blower as-

sembly and retain wires together near the blower motor using

the plastic purse clip provided.

11. To complete the installation, plug the power cord into the

junction box receptacle at the right rear corner of the firebox

outer wrap. See Figure 30.

12. If room permits, the power cord can be located from the out-

side of the unit looking through the junction box access hole

(with the junction box removed), then plug up the power cord

before reinstalling the pre-wired junction box.

13. Once all connections are made electrically, it is recommend-

ed that you test the blower fan control operation by turning

on power to the blower (Caution: 110 Volt). Then apply heat

to the fan control switch inside the firebox with a lighter or

match until blower is activated. Once blower is activated,

check for proper operation. Do not place hands near blower

assembly or other wiring while power is on.

14. Replace blower access plate and/or reinstall the brick liner

panels if provided.

15. This completes the installation of the optional FBB5 Blower

kit accessory.

Note: This blower is equipped with a heat activated fan control

switch. Blower will operate when the firebox warms up,

and will turn off automatically when the firebox cools

down.

REAR COVER PANEL MAY BE

REMOVED TO INSTALL BLOWER

REINSTALL COVER AFTER

BLOWER IS INSTALLED

Figure 28

FAN CONTROL

SWITCH LOCATION

FAN CONTROL WIRES

Figure 29

Figure 30

BLOWER POWER CORD