Sidewall Clearances: The clearance from the inside of the firebox

to perpendicular combustible side wall should not be less than

6". See Figure 1.

Firebox Side and Back Clearances: The firebox outer casing side

and back flanges are zero clearance to combustibles.

Top Framing and Finishing: Combustible framing may rest on

top of standoffs. Combustible finishing materials may extend

to the top standoff screws on the front edge of the outer wrap.

See Figure 2.

Ceiling Clearances: The ceiling height should not be less than 42"

from the top of the hood. See Figure 3.

Mantel Clearances: Vent free firebox models must use the hood

supplied with the firebox, or one of the optional hood kits

available for each model. If a combustible mantel is installed,

it must meet the clearance requirements detailed below.

Grate Clearance: The minimum clearance between the front legs

of the grate and front edge of the firebox is 2".

Leave at least 36" clearance from the front of the firebox.

Any vent-free Gas Log Heater must be “For use with approved

ANSI Z21.11.2 unvented room heater.”
Follow and complete the installation instructions of the gas log set

and the requirements of this firebox.

Check all fittings for leaks before lighting the gas log set.
In planning the installation for the firebox, it is necessary to

determine where the unit is to be installed and whether optional

accessories are desired. Gas supply piping should also be planned

at this time.
A gas shut off must be in this line.

45°

6”

3”

MAX.

PERPENDICULAR
SIDE WALL

FRONT FACE (SIDE)

FIREBOX

(TOP VIEW)

COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS

FIREBOX

STAND OFF

FINISH WITH TRIM KIT OR

NON-COMBUSTIBLE MATERIAL

AS DESIRED.

COMBUSTIBLE

FINISHED WALL

OR MANTEL

2 X 4

HEADER

MANTEL

HOOD

13”

10”

12”

MAX

42”

MIN.

(CEILING TO
TOP OF HOOD)

11 1/2”

MIN.

FIREBOX
FACE

84”

MIN.

(CEILING TO FLOOR)

CEILING

COMBUSTIBLES

ALLOWED

3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX

10”

22”

8”

20”

6 ½”

18”

5”

16”

3 ½”

14”

2”

12 ½”

3/4”

24 ½”

0”

Figure 1

Figure 2

Figure 3

CLEARANCES