The firebox is designed to accept a 3/8-inch gas line for an approved

vent-free gas logset. Have the line installed by a qualified service

person in accordance with all building codes. Consult local building

codes to properly size the gas supply line leading to the 3/8-inch

hook-up at the unit. The state of Massachusetts requires that a

flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox.

See

Figure 11. On models with ceramic brick panels installed, carefully

remove the indented knockout in the ceramic brick panel using a

drill or utility knife. See Figure 12.
When installing optional ceramic fiber side panels into firebox,

lay panel on a flat surface. Remove the gas line knockout (round

depression) in the appropriate side panel using a drill or utility

knife.
After the brick panel knockout is removed, the firebox wrap may

have a round metal knockout that must be removed also. Use a

screwdriver to punch out the metal knockout.
Check gas type. Use only the gas type indicated on the gas log

set rating plate. If the gas listed on the plate is not your type of

gas supply, DO NOT INSTALL. Contact your dealer for proper

model.
Always use an external regulator for all LP fireboxes to reduce the

supply tank pressure to a maximum of 14" w.c. This is in addition

to the regulator fitted to the log set.

WARNING: CONNECTION DIRECTLY TO AN

UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.

Install only a ANSI Z21.11.2 vent-free log set into this firebox.

Figure 11

Extended Hoods
If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that

will extend out 2" farther out into the room. Contact your local dealer for details.

Finishing

All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-

combustible material.
Hearth extensions are recommended, but not required for these fireboxes.

VB4H32BL

Standard Black

VB4H36BL

Standard Black

VB4H42BL

Standard Black

VB4H32BR

Polished Brass

VB4H36BR

Polished Brass

VB4H42BR

Polished Brass

VB4H32SS

Stainless Steel

VB4H36SS

Stainless Steel

VB4H42SS

Stainless Steel

VB4H32HP

Hammered Pewter

VB4H36HP

Hammered Pewter

VB4H42HP

Hammered Pewter

GAS ACCESS HOLES

Figure 12

INSTALLING HOOD (continued)

GAS LINE CONNECTION

Advertising