Eaton 9155 User Manual

Page 8

Advertising
background image

UNITED STATES

8609 Six Forks Road

Raleigh, NC 27615 U.S.A.

Toll Free: 1.800.356.5794

www.eaton.com/powerquality

CANADA

Ontario: 416.798.0112

Toll free: 1.800.461.9166

LATIN AMERICA

South Cone: 54.11.4124.4000

Brazil: 55.11.3616.8500

Andean & Caribbean:

1.949.452.9610

Mexico & Central America:

52.55.9000.5252

EUROPE/MIDDLE EAST/AFRICA

Denmark: 45.3686.7910

Finland: 358.94.52.661

France: 33.1.6012.7400

Germany: 49.0.7841.604.0

Italy: 39.02.66.04.05.40

Norway: 47.23.03.65.50

Portugal: 55.11.3616.8500

Sweden: 46.8.598.940.00

United Kingdom: 44.1753.608.700

ASIA PACIFIC

Australia: 61.2.9693.9366

New Zealand: 64.0.3.343.3314

China: 86.21.6361.5599

HK/Korea/Taiwan: 852.2745.6682

India: 91.11.4223.2300

Singapore/SEA: 65.6825.1668

Eaton, PowerChain Management, ABM,

ConnectUPS, LanSafe, PowerVision,

Powerware Hot Sync, and X-Slot are trade

names, trademarks and/or service marks

of Eaton Corporation or its subsidiaries and

affiliates. All other trademarks are property

of their respective owners.

©2010 Eaton Corporation

All Rights Reserved

Printed in USA

9155FXA

April 2010

TECHNICAL SPECIFICATIONS for 10 AND 15 kVA

POWER
Ratings (kVA/Watts)

8, 10, 12 and 15 kVA at 0.9 power factor

Topology

True double-conversion online UPS

Electrical Input
Nominal Input Voltage

200V-240V with neutral or with optional input transformer

Input Voltage Range

-15%, +10% from nominal at 100% load without

depleting battery

Operating Frequency

50/60 Hz (45 to 65 Hz)

Input Power Factor

P.F >0.99 typical, >0.96 frequency converter

Input Current Distortion

5% THD

ElECtRICAl OUtPUt
Nominal Output Voltage 100/200, 110/220, 120/240 Vac 180° phase displacement;

120/208, 127/220 Vac 120° phase displacement

Output Voltage

Regulation

±1% Static; ±5% dynamic at 100% resistive load change,

<1 ms response time

Efficiency

90% typical

BAttERy
Battery Type

9Ah, sealed, lead-acid, maintenance-free

Battery Runtime

See Battery Runtime Chart

Battery Replacement

Field-replaceable

Charger

Default is 3.4A per battery string. Charger current is

configurable from 0.5A to 25A per string with an overall

maximum of 34A (limited by input current)

Start-On-Battery

Allows start of UPS without utility input

GENERAl
Diagnostics

Full system self-test at startup

UPS Bypass

Automatic on overload or UPS failure

Parallel for Redundancy

and Capacity

Yes, using Powerware Hot Sync technology

Dimensions and Weights See Model Selection Table
Overload

150% for 5 sec / 125% for 1 min (online), (Normal Operation)

110% for 10 min

COMMUNICAtIONS
LCD Display

Graphical LCD with blue backlight

LEDs

(4) LEDs for notice and alarm

Audible Alarms

Yes

Communication Ports

(1) RS-232, (1) relay contact, (1) REPO, (2) environmental input

Communication Slot

(2) X-Slot communication bays

Power Management

Bundled Software Suite CD Software

ENVIRONMENtAl
Operating Temperature

10ºC to +40ºC, +45ºC with 7.5% derating;

Batteries recommended max. +25ºC

Storage Temperature

-15ºC to +25ºC

Relative Humidity

0–95%, non-condensing

Audible Noise

Audible Noise: < 53 dBA at 1 meter (noise less room) typical

Altitude

< 1000m at +40°C, < 3000m at +25°C

CERtIfICAtIONS
Safety Certifications

NOM-0190SCFI-1993, UL 1778, CSA C22.2, No. 107.3;

EN 5502 Class A (CISPR22 Class A) and IEC 60950;

IEC 62040-1-1

EMC Compliance

IEC 62040-2, FCC Part 15, ICES-003, VCCI

Quality

ISO 9001: 2000 and ISO 14001:1996

Markings

UL, cUL, CSA, CE and NOM-NYCE