Empire Comfort Systems FAW-55SPP User Manual

Page 5

Advertising
background image

12428-6-0408

Page 5

4” (102mm) MINIMUM
TO COMBUSTIBLES

4” (102mm) MINIMUM
TO COMBUSTIBLES

WHEN SIDE
REGISTERS ARE
NOT USED UNIT
MAY BE RECESSED
4” (102mm)

5½”(140mm)

16” (406mm)

3 1/4” (83mm)

11½” (292mm)

5½”

(140mm)

8” x 12” (203mm x 305mm) boot. Remove duct and cut to proper

length.

8. Attach 6” x 10” (152mm x 254mm) duct to inner casing with (6)

#10 x 1/2” (13mm) screws provided.

9. Insert rear register into 8” x 12” (203mm x 305mm) boot. Attach

rear register to wall with (2) #10 x 1” (25mm) screws provided.

Locating Furnace On Wall

The furnace is to be located on a wall. The furnace is 16 inches (406mm)

in width and normal 16” (406mm) on center studs will not allow the fur-

nace to be recessed into the wall unless a stud is repositioned.
A template is proved in furnace carton for locating gas line connection.

Also, refer to Figure 2 for positioning the furnace on wall and for locating

gas line connection.
Locating Gas Supply

The gas line can enter the furnace either though the floor or wall. The gas

line opening should be made at this time. Location of the opening will be

determined by the position of floor joists and the valve and union used

for servicing.
Location Electric Supply

A 7/8” (22mm) diameter knockout is provided at the bottom of the left

and right side panels. A three-prong (grounding) plug assembly is located

within the control compartment (bottom) of the furnace. Please remove

7/8” (22mm) knockout from appropriate side panel when routing plug

assembly to an electrical outlet.
Installation of Three-prong (Grounding) Plug Assembly

1. Disconnect nylon cap on 3’ (914mm) plug assembly from nylon plug

on wiring harness. Remove 3’ (914mm) plug assembly from control

compartment (bottom) of the furnace.

2. Remove 7/8” (22mm) knockout from appropriate side panel.

3. Insert nylon cap on 3’ (914mm) plug assembly into the 7/8” (22mm)

hole in the side panel.

4. Connect nylon cap on 3’ (914mm) plug assembly to nylon plug on

the wiring harness.

5. Place 7/8” (22mm) strain relief bushing around the cord of the 3’