For your safety read before lighting, Lighting instructions – Empire Comfort Systems FAW-55SPP User Manual

Page 9

Advertising
background image

12428-6-0408

Page 9

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas

is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

•Do not try to light any appliance.

•Do not touch any electrical switch;

do not use any phone in your building.

•Immediately call your gas supplier from a neighbor’s

phone, Follow the gas supplier’s instructions.

•If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control

knob. Never use tools. If the knob will not push in or turn

by hand, don’t try to repair it; call a qualified service

technician. Force or attempted repair may result in a fire

or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect

the appliance and to replace any part of the control system

and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. Remove control access panel (lower front panel).
5. Turn gas control knob clockwise

to “OFF.”

6. Wait ten (10) minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas, STOP! Fol-

low “B” in the safety information above. If you don’t smell

gas, go to the next step.

7. Remove the pilot access cover located on the combustion

chamber.

8. Find pilot - follow metal tube from gas control. The pilot

is located between the two burner

tubes behind the pilot access

cover.

9. Turn gas control knob counterclockwise

to “Pilot.”

10. Push and hold red reset button down completely and

repeatedly push the ignitor button until the pilot burner

is lit. Pilot may also be lit with a match. Continue to hold

the red rest button down for about one (1) minute after

the pilot is lit. Release button and it will pop back up. Pilot

should remain lit. If it goes out, repeat step 5 through 10.

• If button does not pup up when released, stop

and immediately call a qualified service

technician or gas supplier.

• If the pilot will not stay lit after several tries,

turn the gas control knob to “OFF” and call

your service technician or gas supplier.

11. Replace pilot access cover.
12. Turn gas control knob counterclockwise

to “ON.”

13. Replace control access panel (lower front panel).
14. Turn on all electric power to the appliance.
15. Set thermostat to desired setting.

GAS CONTROL KNOB SHOWN

IN “OFF” POSITION.

THERMOCOUPLE

PILOT BURNER

TO TURN OFF GAS TO APPLIANCE

1. Set the thermostat to lowest setting.
2. Turn off all electric power to appliance if service is to be

performed.

3. Remove control access panel (lower front panel).

4. Push in gas control knob slightly and turn clockwise

to “OFF.” Do not force.

5. Replace control access panel (lower front panel).

Advertising