Setting up console communication, Setting up console communication o – Extreme Networks Px Series User Manual

Page 24

Advertising
background image

2-6

Px Series Application Switch Installation and Configuration Guide

If the application switch passes the POST, the MGMT LED blinks at a slow rate (1 blink
per second). If the application switch fails the POST, the MGMT LED shows a solid
yellow light.

Setting Up Console Communication

To manage the application switch locally, you must connect to the management console
to configure the switch’s Ethernet management port using a serial connection. This
section describes how to to configure the SummitPx1 for communication with the
console interface.

There are four ports on the application switch:

GBIC 1000bT network interface port

10/100BT Ethernet management port

Serial console and modem management ports

Any workstation with a Telnet facility can communicate with the application switch
over a TCP/IP network. Telnet is enabled by default. Use Telnet to connect to either the
10/100 Mbps Ethernet management port, or to the Gigabit Ethernet network interface
port, after configuring their IP addresses via the serial port.

The 10/100BT Ethernet management port allows the CPU to upload and download
images on a network that is seperate from the data network. This allows the data
network to be outside a firewall while the management port is inside the firewall.

You use the serial management ports for your initial communication with the device, in
order to configure the management and network interface ports. The serial ports use a
RJ45 connector. The SummitPx1 is supplied with an RJ45-to-DB9 converter and ethernet

SPx1_front

Unit status

LEDs

Network Interface

port

Ethernet

Management

LEDs and port

Serial

Management

ports